Steel Requirements for RCC Elements | Foundation Column beam and slab |
1. Main reinforcements
(a) At least 2 bars and not more than 6 bars in one layer.
(b) 8 or 10 mm dia. bars for slabs. For beams 12, 16, 20, 22, 25 or 36 mm bars may be used.
(c) Minimum reinforcements
pt, min =
(d) Maximum reinforcement = 4.0% of gross area.
(e) Bars less than 32 mm dia. may be bundled but bars larger than 32 mm shall not be bundled.
2. Shear reinforcement:
(a) Should go around outermost tension and compression bars.
(b) If no compression steel is used, provide two suspender bars of diameter 10 mm.
(c) Maximum spacing shall be: 0.75 d for vertical shear reinforcement, and d for inclined stirrups
at 45°. In no case it should not be more than 300 mm.
(d) Minimum reinforcement shall be such that ≥ .
(e) 6, 8, 10, 12 mm bars are used for shear reinforcement.
(f) Usually 2 legged reinforcements are provided. Sometimes to avoid too close spacing 4 or 6
legged bars are provided.
(g) If depth of beam exceeds 750 mm, side reinforcements are provided at the rate of 0.1% of web
area. Spacing shall not exceed 300 mm.